In the same way, firmware updates and fast loading of device configurations are possible. For more information about the LEDs, see Section 8. For terminal block assignment, see Section 8. Thanks to its ultra-compact dimensions, the VIP XD is particularly well suited to installation in cabinets or consoles where space is at a premium. Select a suitable location for installation that guarantees to meet the environmental.

The VIP XD generates heat during operation, so you should ensure that there is adequate ventilation and enough clearance between the unit and heat-sensitive objects or equipment. Avoid locations exposed to direct sunlight. The audio version of the VIP XD has two audio ports for audio line signals as well as a microphone input and a loudspeaker output. The audio signals are transmitted two-way and in sync with the video signals.

As a result, you can connect a speaker or door intercom system at the destination point, for example. If possible you should use the line ports of the intercom for transmitting audio signals on the intercom systems.

The following specifications should be complied with in all cases. Impedance 9 kOhm typ. Impedance 16 Ohm min. Impedance 2 kOhm typ. Impedance 4 Ohm min. Connect the loudspeaker cords to the SPK connections on the push-in terminal.

The bi-directional data interface is used to control units connected to the VIP XD, for example a control panel for dome cameras with motorized lens. The range of controllable equipment is expanding constantly. The manufacturers of the relevant equipment provide specific information on installation and control.

Please take note of the appropriate documentation when installing and operating the unit to. The documentation contains important safety instructions and information about permitted uses. The alarm inputs are used to connect to external alarm devices such as door contacts or sensors.

With the appropriate configuration, an alarm sensor can automatically connect the VIP XD to a particular sender, for example. X Connect the lines to the appropriate terminals on the orange terminal block IN1 to IN4 and check that the connection is secure.

The output can also be configured to automatically activate sirens or other alarm units in response to an alarm signal. The relay output is also located on the orange terminal block see. X Connect the lines to the appropriate terminals of the orange terminal block R and check that the connection is secure. Where necessary, use suitable equipment to ensure that the power supply is free from interference such as voltage surges, spikes or voltage drops.

Ensure that the correct primary adapter is attached to the power supply unit and that a suitable power outlet is available. Plug the power supply unit into the grounded power outlet. The unit is ready for operation as soon as the operating status LED stops flashing red during start-up and lights up green.

Provided the network connection has been correctly made, the green L LED also lights up. The flashing orange T LED indicates data traffic on the network. The Configuration Manager program can be found on the product CD contained in the scope. This program allows you to implement and set up new video servers in the. Using the Configuration Manager to set all parameters in the VIP XD is an alternative to configuration by means of a Web browser, as described in chapter 5 of this manual.

Follow the on-screen instructions. Double-click the icon on the desktop or start the program via the Start menu. After the program has started, the network is immediately searched for compatible video servers. To do this, right-click the entry for the unit. Click Unit network settings The unit reboots and the IP address is valid.

If required, enter an appropriate subnet mask for the IP address, and additional network data. You must reboot to activate the new IP address, a new subnet mask or a gateway IP address. You can trigger the reboot directly with the assistance of the Configuration Manager. X Right-click the entry for the unit in the list in the left section of the window and select the Reset command from the context menu.

You can check and set additional parameters with the assistance of the Configuration Manager. You can find detailed information on this in the documentation for this program.

This option is an alternative to configuration using the Configuration Manager program and is considerably richer in function and more convenient than configuration using the terminal program. If necessary, you can install the program from the product CD supplied. The following default address is preset at the factory: If you do not connect, the unit may have reached its maximum number of connections.

If the VIP XD is password protected against unauthorized access, the Web browser displays a corresponding message and prompts you to enter the password when you attempt to access protected areas. Enter the user name and associated password in the corresponding text fields. Click OK. If the password is entered correctly, the Web browser displays the page that was called up. This is because communication via the network is not enabled until the Identity and Password parameters have been set and successfully authenticated see.

You can view the current settings by opening one of the configuration screens. You can change the settings by entering new values or by selecting a predefined value from a list field. All parameter groups are described in this chapter in the order in which they are listed in the configuration menu, from the top of the screen to the bottom. The settings in the configuration menu should only be processed or modified by expert users or system support personnel. Click one of the menu items in the left window margin.

The corresponding submenu is displayed. Click one of the entries in the submenu. The Web browser opens the corresponding page. Each configuration screen shows the current settings. X After each change, click Set to save the change. Save each change with the associated Set button. Clicking the Set button saves the settings only in the current field. Changes in any other fields are ignored. Welcome to ManualMachine. We have sent a verification link to to complete your registration.

Log In Sign Up. Forgot password? Enter your email address and check your inbox. Please check your email for further instructions. Enter a new password. DOC V4. We have sent a verification link to to complete your registration. Log In Sign Up. Forgot password? Enter your email address and check your inbox.

Please check your email for further instructions. Enter a new password. In such cases, have the unit checked by Bosch Security Systems. Safe operation is no longer possible in the following cases: — if there is visible damage to the unit or power cables, — if the unit no longer operates correctly, — if the unit has been exposed to rain or moisture, — if foreign bodies have penetrated the unit, — after long storage under adverse conditions, or — after exposure to extreme stress in transit.

The documentation contains important safety instructions and information about permitted uses. Any other actions may lead to personal injury, damage to property or damage to the equipment. The power supply unit does not contain any user-serviceable parts. International, national and any regional electrical engineering regulations must be followed at all times.

The manual describes the installation and operation of the unit. This symbol indicates that failure to follow the safety instructions described may endanger persons and cause damage to the unit or other equipment. It is associated with immediate, direct hazards. This symbol refers to features and indicates tips and information for easier, more convenient use of the unit. In the event of questions concerning the use of the unit which are not answered in this manual, please contact your sales partner or: Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 Grasbrunn Germany www.

Please make a note of this information before installation, if necessary, so as to have it to hand in case of questions or when ordering spare parts.

Arrange for the unit to be checked by Bosch Security Systems if you find any damage. You can only view or download manuals with. Sign Up and get 5 for free. Upload your files to the site. You get 1 for each file you add. Get 1 for every time someone downloads your manual. Buy as many as you need. View and download manuals available only for. Register and get 5 for free. Upload manuals that we do not have and get 1 for each file.